BIRLA CABLE LTD.

STRUCTURED CABLES

CAT 6A 4 PAIR 23AWG U/ FTP LSZH CABLE

Ipsum

Typical Cross section

Electrical Characteristics:

Conductor Resistance@20°C Max. 9.38 Ω/100m
Conductor Resistance Unbalance Max. 5 %
Capacitance Earth Unbalance Max. 330 pF/100m
Insulation Resistance 5000 Mohm.km(min)
Dielectric Strength DC 1500V/Min
Propagation Delay @ 1 , 10 , 100 & 500 MHz Max. 570, 545, 538 & 536 ns/100 m
Propagation DeLay Skew 1 –500 MHz Max. 45 ns/100 m

Description:

Conductor : 23AWG Solid Annealed Bare Copper Conductor
Insulation : Foamed Polyethylene, diameter 1.3mm(nom)
Pair Screening : Each pair wrapped with Aluminium/Polyester(Mylar)Tape,
Laid Up : Four Individually Screened pairs stranded into cable core.
Drain Wire : Annealed Tinned Copper Wire
Overall Screening : None
Outer Sheathing : LSZH Compound, Colour: Light Blue or Grey RAL7035
Cable Diameter : 7.2 ± 0.50 mm

Features:

  • Generally complied requirements of ISO 11801 Class EA , TIA/EIA 568 C.2
  • Category 6A and IEC 61156-5
  • Packaged in wooden Spool.
  • Cable Characterized up to 500 MHz,
  • RoHS& REACH compliant
  • Flammability; IEC 60332-1-2

Technical Details

Freq (MHZ) Attenuation (dB/100m) NEXT (dB) PSNEXT (dB) ACRF (ELFEXT)(dB) PSACRF [PSELFEXT] (dB) Return Loss
(dB)
Max. Min. Min. Min. Min. Min.
4 4.2 63 60.5 51.2 48.2 19
8 5.8 58.2 55.6 45.2 42.2 19
10 6.5 56.6 54 43.3 40.3 19
16 8.2 53.2 50.6 39.2 36.2 18
20 9.2 51.6 49 37.2 34.2 17.5
25 10.2 50 47.3 35.3 32.3 17
31.25 11.5 48.4 45.7 33.4 30.4 16.5
62.5 16.4 43.4 40.6 27.3 24.3 14
100 20.9 39.9 37.1 23.3 20.3 12
200 30.1 34.8 31.9 17.2 14.2 9
250 33.9 33.1 30.2 15.3 12.3 8
300 37.4 31.7 28.8 13.7 10.7 7.2
400 43.7 28.7 25.8 11.2 8.2 6
500 49.3 26.1 23.2 9.3 6.3 6
650 56.9 23 20.2 7 4 6

Note:

Supply cable guaranteed to pass 70m Channel test as per ANSI/TIA-568-C.2 Category 6a

Colour Code:

Pair 1 : White/Blue Strip -Blue
Pair 2 : White/Orange Strip -Orange
Pair 3 : White/Green Strip-Green
Pair 4 : White/Brown Strip-Brown

Standard Length & Packing:

305m Wooden Spool Dimension : 13 X 6 X 14 inches
Box : 14 X 14 X 15 Inches

Mechanical Properties:

MBR installed(mm) : : 8 x OD
Max. Pulling force : : 60N

Thermal Characteristics:

Operating Temperature : - 10°C to +60°C
Installation Temperature : -0°C to +50°C